List of parameters
Parameters
1-437
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the maximum torque/force generating current as a result if all current limits.
Description: Displays the upper torque limit of all torque limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
Description: Displays the upper force limit of all force limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
Description: Displays the lower torque limit of all torque limits.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529, p1532
r1533 Current limit force-generating total / Iq_max total
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5640, 5722,
6640
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1534 CO: Torque limit upper total / M_max upper total
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1534 CO: Force limit upper, total / F_max upper total
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r1535 CO: Torque limit lower total / M_max lower total
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1610, 5620,
5630, 5640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]