List of parameters
Parameters
1-227
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the inverted status of the digital inputs.
Dependency: Refer to: r0722
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI: Digital input
DI/DO: Bidirectional Digital Input/Output
Description: Displays the inverted status of the digital inputs.
r0723.0...15 BO: CU digital inputs, status inverted / CU DI status inv
CU_S Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X122.1/X121.1) High Low -
01 DI 1 (X122.2/X121.2) High Low -
02 DI 2 (X122.3/X121.3) High Low -
03 DI 3 (X122.4/X121.4) High Low -
04 DI 4 (X132.1) High Low -
05 DI 5 (X132.2) High Low -
06 DI 6 (X132.3) High Low -
07 DI 7 (X132.4) High Low -
08 DI/DO 8 (X122.7/X121.7) High Low -
09 DI/DO 9 (X122.8/X121.8) High Low -
10 DI/DO 10 (X122.10/X121.10) High Low -
11 DI/DO 11 (X122.11/X121.11) High Low -
12 DI/DO 12 (X132.7) High Low -
13 DI/DO 13 (X132.8) High Low -
14 DI/DO 14 (X132.10) High Low -
15 DI/DO 15 (X132.11) High Low -
r0723.0...11 BO: CX digital inputs, status inverted / CX DI status inv
CU_CX32 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 2220, 2230,
2231
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X122.1) High Low -
01 DI 1 (X122.2) High Low -
02 DI 2 (X122.3) High Low -
03 DI 3 (X122.4) High Low -
08 DI/DO 8 (X122.7) High Low -
09 DI/DO 9 (X122.8) High Low -
10 DI/DO 10 (X122.10) High Low -
11 DI/DO 11 (X122.11) High Low -