Siemens SINAMICS S Series - r3662 CO: VSM input line supply voltage u2 - u3; VSM inp u2�u3; r3662[0...n] CO: VSM input line supply voltage u2 - u3; VSM inp u2�u3; r3664.0...1 BO: VSM temperature evaluation, status; VSM temp status; r3664[0...n] CO: VSM temperature evaluation, status; VSM temp status

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-725
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the voltage between L2 and L3.
Dependency: Refer to: r0025, r0072, p3660
Note: X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
The absolute voltage value resulting from the phase voltages is displayed in r0072[1] and smoothed in r0025[1].
Description: Displays the voltage between L2 and L3.
Dependency: Refer to: p3660
Note: X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
Description: Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency: Refer to: p3665, r3666, p3667, p3668
Description: Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
r3662 CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950,
9880
P-Group: Closed-loop control Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3662[0...n] CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: -
P-Group: Closed-loop control Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3664.0...1 BO: VSM temperature evaluation, status / VSM temp status
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 9886
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Temperature alarm threshold exceeded Yes No -
01 Temperature fault threshold exceeded Yes No -
r3664[0...n] CO: VSM temperature evaluation, status / VSM temp status
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: p0150 Func. diagram: 9886
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -