List of parameters
Parameters
1-725
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the voltage between L2 and L3.
Dependency: Refer to: r0025, r0072, p3660
Note: X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
The absolute voltage value resulting from the phase voltages is displayed in r0072[1] and smoothed in r0025[1].
Description: Displays the voltage between L2 and L3.
Dependency: Refer to: p3660
Note: X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
Description: Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency: Refer to: p3665, r3666, p3667, p3668
Description: Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
r3662 CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950,
9880
P-Group: Closed-loop control Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3662[0...n] CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: p0150 Func. diagram: -
P-Group: Closed-loop control Units group: 5_3 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3664.0...1 BO: VSM temperature evaluation, status / VSM temp status
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 9886
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Temperature alarm threshold exceeded Yes No -
01 Temperature fault threshold exceeded Yes No -
r3664[0...n] CO: VSM temperature evaluation, status / VSM temp status
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: p0150 Func. diagram: 9886
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -