EasyManua.ls Logo

Siemens SINAMICS S Series - p9330 SI motion standstill tolerance (Motor Module); SI Mtn SOS Tol MM; p9331[0...3] SI motion SLS limit values (Motor Module); SI Mtn SLS lim MM

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-978
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency: Refer to: p9530
Refer to: C01707
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operational Stop
Description: Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency: Refer to: p9530
Refer to: C01707
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operational Stop
Description: Sets the limit values for the function "Safely-Limited Speed" (SLS).
Index: [0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency: Refer to: p9363, p9531
Refer to: C01714
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed
p9330 SI motion standstill tolerance (Motor Module) / SI Mtn SOS Tol MM
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [mm] 100.000 [mm] 1.000 [mm]
p9330 SI motion standstill tolerance (Motor Module) / SI Mtn SOS Tol MM
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [°] 100.000 [°] 1.000 [°]
p9331[0...3] SI motion SLS limit values (Motor Module) / SI Mtn SLS lim MM
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [mm/min] 1000000.00 [mm/min] 2000.00 [mm/min]

Table of Contents