Parameters
List of parameters
1-1020
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: C01711
Description: Displays result list 2 that, for the data cross-check between the monitoring channels, led to the fault.
Index: [0] = Result list, second channel
[1] = Result list, drive
Dependency: Refer to: C01711
Description: Displays the actual motor-side position actual value for the motion monitoring functions on the Control Unit.
06 Actual value > upper limit, SG1 Yes No -
07 Actual value > lower limit, SG1 Yes No -
08 Actual value > upper limit, SG2 Yes No -
09 Actual value > lower limit, SG2 Yes No -
10 Actual value > upper limit, SG3 Yes No -
11 Actual value > lower limit, SG3 Yes No -
12 Actual value > upper limit, SG4 Yes No -
13 Actual value > lower limit, SG4 Yes No -
16 Actual value > upper limit, SBR Yes No -
17 Actual value > lower limit, SBR Yes No -
r9711[0...1] SI motion diagnostics result list 2 / SI Mtn res_list 2
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value > upper limit, SN1+ Yes No -
01 Actual value > lower limit, SN1+ Yes No -
02 Actual value > upper limit, SN1- Yes No -
03 Actual value > lower limit, SN1- Yes No -
04 Actual value > upper limit, SN2+ Yes No -
05 Actual value > lower limit, SN2+ Yes No -
06 Actual value > upper limit, SN2- Yes No -
07 Actual value > lower limit, SN2- Yes No -
08 Actual value > upper limit, SN3+ Yes No -
09 Actual value > lower limit, SN3+ Yes No -
10 Actual value > upper limit, SN3- Yes No -
11 Actual value > lower limit, SN3- Yes No -
12 Actual value > upper limit, SN4+ Yes No -
13 Actual value > lower limit, SN4+ Yes No -
14 Actual value > upper limit, SN4- Yes No -
15 Actual value > lower limit, SN4- Yes No -
16 Actual value > upper limit, n_x+ Yes No -
17 Actual value > lower limit, n_x+ Yes No -
18 Actual value > upper limit, n_x- Yes No -
19 Actual value > lower limit, n_x- Yes No -
20 Actual value > upper limit, modulo Yes No -
21 Actual value > lower limit, modulo Yes No -
r9712 SI motion diagnostics position action value motor side / SI Mtn s_act mot
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -