Parameters
List of parameters
1-204
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Inhibits the calculation of reference parameters (e.g. p2000) when automatically calculating the motor and control
parameters (p0340, p3900).
Values: 0: No
1: Yes
Note: 0: The automatic calculation (p0340, p3900) overwrites the reference parameters.
1: The automatic calculation (p0340, p3900) does not overwrite the reference parameters.
Description: This parameter is used to calculate all parameters that depend on the technology of the application (p0500).
All of the parameters are calculated that can also be determined using p0340 = 5.
Values: 0: No calculation
1: Complete parameterization
Note: At the end of the calculations, p0578 is automatically set to 0.
Description: Sets the input terminal for the measuring probe for speed actual value measurement.
Values: 0: No meas probe
1: DI/DO 9 (X122.8/X121.8)
2: DI/DO 10 (X122.10/X121.10)
3: DI/DO 11 (X122.11/X121.11)
4: DI/DO 13 (X132.8)
5: DI/DO 14 (X132.10)
6: DI/DO 15 (X132.11)
Dependency: Refer to: p0581, p0728
Refer to: A07498
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CU310, CX32, NX10 and NX15, only DI/DO 9, 10, 11 can be selected as fast inputs (refer to the Equipment
Manual).
Note: DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
p0573 Inhibit automatic reference value calculation / Calc ref inhib
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p0578[0...n] Calculate parameters that are dependent on the technology/units / Calc techn par
SERVO, VECTOR Can be changed: C2(5), T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p0580 Measuring probe, input terminal / MT input terminal
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 0