List of parameters
Parameters
1-777
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: r4022
Note: DI: Digital input
DI/DO: Bidirectional Digital Input/Output
Description: Displays the inverted status of the digital inputs of terminal module 15 (TM15).
Dependency: Refer to: r4022, r4024, r4025
Notice: For the BICO interconnection of the connector output (CO) only bit 00 ... bit 15 are transferred.
Note: DI/DO: Bidirectional Digital Input/Output
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X522.1) High Low 9660
01 DI 1 (X522.2) High Low 9660
02 DI 2 (X522.3) High Low 9660
03 DI 3 (X522.4) High Low 9660
08 DI/DO 0 (X521.1) High Low 9661
09 DI/DO 1 (X521.2) High Low 9661
10 DI/DO 2 (X521.3) High Low 9662
11 DI/DO 3 (X521.4) High Low 9662
r4023.0...23 CO/BO: TM15DI/DO digital inputs, status inverted / TM15D DI stat inv
TM15DI_DO Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 9400, 9401,
9402
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) High Low -
01 DI/DO 1 (X520.3) High Low -
02 DI/DO 2 (X520.4) High Low -
03 DI/DO 3 (X520.5) High Low -
04 DI/DO 4 (X520.6) High Low -
05 DI/DO 5 (X520.7) High Low -
06 DI/DO 6 (X520.8) High Low -
07 DI/DO 7 (X520.9) High Low -
08 DI/DO 8 (X521.2) High Low -
09 DI/DO 9 (X521.3) High Low -
10 DI/DO 10 (X521.4) High Low -
11 DI/DO 11 (X521.5) High Low -
12 DI/DO 12 (X521.6) High Low -
13 DI/DO 13 (X521.7) High Low -
14 DI/DO 14 (X521.8) High Low -
15 DI/DO 15 (X521.9) High Low -
16 DI/DO 16 (X522.2) High Low -
17 DI/DO 17 (X522.3) High Low -
18 DI/DO 18 (X522.4) High Low -
19 DI/DO 19 (X522.5) High Low -
20 DI/DO 20 (X522.6) High Low -
21 DI/DO 21 (X522.7) High Low -
22 DI/DO 22 (X522.8) High Low -
23 DI/DO 23 (X522.9) High Low -