List of parameters
Parameters
1-561
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For clock synchronous operation, bit 12 to 15 to transfer the sign-of-life are reserved in status word 2 - and may not
be freely interconnected.
Description: Selects bits to be sent to the PROFIBUS/PROFINET master.
The individual bits are combined to form free status word 3.
Index: [0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency: Refer to: p2088, r2089
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Selects bits to be sent to the PROFIBUS/PROFINET master.
The individual bits are combined to form free status word 4.
Index: [0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
p2082[0...15] BI: Binector-connector converter status word 3 / Bin/con ZSW3
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TB30, TM15DI_DO,
TM31, TM41, VEC-
TOR
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2472
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2083[0...15] BI: Binector-connector converter status word 4 / Bin/con ZSW4
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TB30, TM15DI_DO,
TM31, TM41, VEC-
TOR
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2472
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0