Siemens SINAMICS S Series - p0155[0...n] Voltage Sensing Module, activate;de-activate; VSM act;deact; r0156[0...n] Voltage Sensing Module, active;inactive; VSM act;inact; r0157[0...n] Voltage sensing module, EPROM data version; VSM EPROM version; r0157 DRIVE-CLiQ Hub EPROM data version; Hub EPROM version

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-105
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Setting to activate/de-activate a Voltage Sensing Module (VSM).
Values: 0: De-activate component
1: Activate component
2: Component, de-activate and not present
Recommend.: After inserting a component, before activating, first wait for Alarm A01317.
Dependency: Refer to: r0156
Refer to: A01317
Description: Displays the "active" or "inactive" state of a Voltage Sensing Module (VSM).
Values: 0: Component inactive
1: Component active
Dependency: Refer to: p0155
Description: Displays the version of the EPROM data of the Voltage Sensing Module (VSM).
Description: Displays the version of the EPROM data of the DRIVE-CLiQ Hub Module Cabinet (DMC).
p0155[0...n] Voltage Sensing Module, activate/de-activate / VSM act/deact
VECTOR Can be changed: C1(4), T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: p0150 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 1
r0156[0...n] Voltage Sensing Module, active/inactive / VSM act/inact
VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dynamic index: p0150 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 -
r0157[0...n] Voltage sensing module, EPROM data version / VSM EPROM version
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: p0150 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0157 DRIVE-CLiQ Hub EPROM data version / Hub EPROM version
DMC20 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -