List of parameters
Parameters
1-105
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Setting to activate/de-activate a Voltage Sensing Module (VSM).
Values: 0: De-activate component
1: Activate component
2: Component, de-activate and not present
Recommend.: After inserting a component, before activating, first wait for Alarm A01317.
Dependency: Refer to: r0156
Refer to: A01317
Description: Displays the "active" or "inactive" state of a Voltage Sensing Module (VSM).
Values: 0: Component inactive
1: Component active
Dependency: Refer to: p0155
Description: Displays the version of the EPROM data of the Voltage Sensing Module (VSM).
Description: Displays the version of the EPROM data of the DRIVE-CLiQ Hub Module Cabinet (DMC).
p0155[0...n] Voltage Sensing Module, activate/de-activate / VSM act/deact
VECTOR Can be changed: C1(4), T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: p0150 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 1
r0156[0...n] Voltage Sensing Module, active/inactive / VSM act/inact
VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dynamic index: p0150 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 -
r0157[0...n] Voltage sensing module, EPROM data version / VSM EPROM version
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: p0150 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0157 DRIVE-CLiQ Hub EPROM data version / Hub EPROM version
DMC20 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals