Description: Displays the actual output voltage at the analog outputs of the Terminal Board 30 (TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Displays the actual output voltage in V when set as voltage output.
Displays the actual output voltage in mA when set as current output.
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency: The type of the analog output AO x (voltage or current output) is set using p4076.
Refer to: r4076, p4076
Note: AO: Analog Output
Description: Activates the absolute value generation for the analog outputs of the Terminal Board 30 (TB30).
Values: 0: No absolute value generation
1: Absolute value generation switched-in
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Activates the absolute value generation for the analog outputs of terminal module 31 (TM31).
Values: 0: No absolute value generation
1: Absolute value generation switched-in
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
r4074[0...1] TB30 analog outputs, actual output voltage / TB30 AO V_outp
TB30 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r4074[0...1] TM31 analog outputs, actual output voltage/current / TM31 AO V/I_outp
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p4075[0...1] TB30 analog outputs, activate absolute value generation / TB30 AO absVal act
TB30 Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p4075[0...1] TM31 analog outputs, activate absolute value generation / TM31 AO absVal act
TM31 Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0