Parameters
List of parameters
1-1028
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: C01711
Description: Displays result list 5, that for the data cross-check with the control, led to the fault.
Index: [0] = Result list, second channel
[1] = Result list, drive
Dependency: Refer to: C01711
Description: Displays result list 5, that for the data cross-check with the control, led to the fault.
Index: [0] = Result list, second channel
[1] = Result list, drive
20 Actual value > upper limit, SN12+ Yes No -
21 Actual value > lower limit, SN12+ Yes No -
22 Actual value > upper limit, SN12- Yes No -
23 Actual value > lower limit, SN12- Yes No -
r9737[0...1] SI motion diagnostics result list 5 / SI Mtn res_list 5
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value > upper limit, SN13+ Yes No -
01 Actual value > lower limit, SN13+ Yes No -
02 Actual value > upper limit, SN13- Yes No -
03 Actual value > lower limit, SN13- Yes No -
04 Actual value > upper limit, SN14+ Yes No -
05 Actual value > lower limit, SN14+ Yes No -
06 Actual value > upper limit, SN14- Yes No -
07 Actual value > lower limit, SN14- Yes No -
08 Actual value > upper limit, SN15+ Yes No -
09 Actual value > lower limit, SN15+ Yes No -
10 Actual value > upper limit, SN15- Yes No -
11 Actual value > lower limit, SN15- Yes No -
12 Actual value > upper limit, SN16+ Yes No -
13 Actual value > lower limit, SN16+ Yes No -
14 Actual value > upper limit, SN16- Yes No -
15 Actual value > lower limit, SN16- Yes No -
16 Actual value > upper limit, SN17+ Yes No -
17 Actual value > lower limit, SN17+ Yes No -
18 Actual value > upper limit, SN17- Yes No -
19 Actual value > lower limit, SN17- Yes No -
20 Actual value > upper limit, SN18+ Yes No -
21 Actual value > lower limit, SN18+ Yes No -
22 Actual value > upper limit, SN18- Yes No -
23 Actual value > lower limit, SN18- Yes No -
r9738[0...1] SI motion diagnostics result list 6 / SI Mtn res_list 6
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Actual value > upper limit, SN19+ Yes No -
01 Actual value > lower limit, SN19+ Yes No -
02 Actual value > upper limit, SN19- Yes No -