Parameters
List of parameters
1-828
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the edge mode for digital input 8 ... 15 of terminal module 17 (TM17).
Assignment of the digital inputs to the bits:
DI 8: r4212.1 ... 0
DI 9: r4212.3 ... 2
DI 10: r4212.5 ... 4
DI 11: r4212.7 ... 6
DI 12: r4212.9 ... 8
DI 13: r4212.11 ... 10
DI 14: r4212.13 ... 12
DI 15: r4212.15 ... 14
Possible edge modes:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> rising - rising edge
Bit x, y = 1, 0 --> falling - falling edge
Bit x, y = 1, 1 --> rising - falling edge or falling - rising edge
Note: DI: Digital input
Description: Displays the edge mode for digital input 8 ... 15 of terminal module 15 (TM15).
Assignment of the digital inputs to the bits:
DI 8: r4212.1 ... 0
DI 9: r4212.3 ... 2
DI 10: r4212.5 ... 4
DI 11: r4212.7 ... 6
DI 12: r4212.9 ... 8
DI 13: r4212.11 ... 10
DI 14: r4212.13 ... 12
DI 15: r4212.15 ... 14
Possible edge modes:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> rising - rising edge
Bit x, y = 1, 0 --> falling - falling edge
Bit x, y = 1, 1 --> rising - falling edge or falling - rising edge
Note: DI: Digital input
r4212 TM17 edge mode digital input 8 ... 15 / TM17 EdgMd DI 8-15
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4212 TM15 edge mode digital input 8 ... 15 / TM15 EdgMd DI8-15
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -