List of faults and alarms
Faults and Alarms
3-1711
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
F34207 (N, A) VSM: Temperature fault threshold exceeded
Drive object: All objects
Reaction: A_INFEED: OFF2 (NONE, OFF1)
SERVO: NONE
VECTOR: NONE
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The temperature (r3666) measured using the Voltage Sensing Module (VSM) has exceeded the threshold value
(p3668).
This fault can only be initiated if the temperature evaluation was activated (p3665 = 2 for a KTY sensor or p3665 =
1 for a PTC sensor).
Fault value (r0949, interpret decimal):
The hundred thousands and ten thousands position specifies the component number of the VSM where the fault
occurred.
Remedy: - check the fan.
- reduce the power.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
A34211 (F, N) VSM: Temperature alarm threshold exceeded
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The temperature (r3666) measured using the Voltage Sensing Module (VSM) has exceeded the threshold value
(p3667).
Alarm value (r2124, interpret decimal):
The hundred thousands and ten thousands position specifies the component number of the VSM where the fault
occurred.
Remedy: - check the fan.
- reduce the power.
Reaction upon F: A_INFEED: NONE (OFF1, OFF2)
SERVO: NONE
VECTOR: NONE
Acknowl. upon F: IMMEDIATELY (POWER ON)
Reaction upon N: NONE
Acknowl. upon N: NONE
N34800 (F) VSM: Group signal
Drive object: All objects
Reaction: A_INFEED: OFF2 (NONE, OFF1)
SERVO: NONE (OFF1, OFF2, OFF3)
VECTOR: NONE (OFF1, OFF2, OFF3)
Acknowledge: NONE
Cause: The Voltage Sensing Module (VSM) has detected at least one fault.
Remedy: Evaluates other actual messages.
Reaction upon F: A_INFEED: OFF2 (NONE, OFF1)
SERVO: NONE (OFF1, OFF2, OFF3)
VECTOR: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY