List of parameters
Parameters
1-413
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
Description: Sets the signal source to set the integrator setting value (p1478).
Dependency: Refer to: p1478, p1479
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
Description: Sets the signal source for the integrator setting value for the velocity controller.
The signal to set this integrator setting value is interconnected via p1477.
Dependency: Refer to: p1477, p1479
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
Description: Sets the signal source for the integrator setting value for the velocity controller.
The signal to set this integrator setting value is interconnected via p1477.
Dependency: Refer to: p1477, p1479
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For the interface mode "SIMODRIVE 611 universal" (p2038 = 1), p1477 and p1478 are used for the signal STW2.6
(integrator inhibit, speed controller).
p1477[0...n] BI: Set velocity controller integrator value / v_ctrl integ set
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 2520, 5040,
5042, 5210
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0
p1478[0...n] CI: Speed controller integrator setting value / n_ctr integ_setVal
SERVO Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5040, 5042,
5210
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0
p1478[0...n] CI: Velocity controller, integrator value / v_ctr integ_setVal
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 5040, 5042,
5210
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0