Description: Sets the force constant of the synchronous motor.
p0316 = 0: The force constant is calculated from the motor data.
p0316 > 0: The selected value is used as force constant.
Dependency: Refer to: r0334, r1937
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Voltage constant for synchronous motors set by the motor identification.
Units for rotating synchronous motors: Vrms/(1000 RPM), phase-to-phase
Dependency: Refer to: r1938
Note: This parameter is not used for induction motors (p0300 = 1xx).
Description: Sets the voltage constant for synchronous motors.
Units for linear synchronous motors: Vrms s/m, phase
Dependency: Refer to: r1938
Note: The parameter is automatically preset for motors from the motor list (p0301).
Description: Induction motors:
Sets the rated motor magnetizing current.
For p0320 = 0.000 the magnetizing current is internally calculated and displayed in r0331.
Synchronous motors:
Sets the rated motor short-circuit current.
p3016 Motor force constant / MotId kT
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: 29_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.00 [N/Arms] 1000.00 [N/Arms] 0.00 [N/Arms]
p3017 Motor identification - voltage constant / MotId kE
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.0 [Vrms] 10000.0 [Vrms] 0.0 [Vrms]
p3017 Motor identification - voltage constant / MotId kE
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
0.0 [Vrms s/m] 1000.0 [Vrms s/m] 0.0 [Vrms s/m]
p3020 Motor identification - rated magnetizing current / MotId I_mag_rated
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.000 [Arms] 5000.000 [Arms] 0.000 [Arms]