Parameters
List of parameters
1-456
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the proportional gain of the current model controller. This value is automatically preset using p3900 or p0340
when commissioning has been completed.
Description: Sets the proportional gain of the current model controller. This value is automatically preset using p3900 or p0340
when commissioning has been completed.
Description: Displays the effective P gain of the current model controller.
Description: Displays the effective integral time of the current model controller.
Description: Displays the effective flux setpoint of the current model. The value is referred to the rated motor flux.
p1629[0...n] Current model controller P gain / I_mod_ctrl Kp
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.000 100000.000 0.000
p1630[0...n] Current model controller integral time / I_ctrl Tn
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 4
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
0.00 [ms] 10000.00 [ms] 0.00 [ms]
r1631 Current model controller, P gain effective / I_mod ctrl Kp eff
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- - -
r1632 Current model controller integral time effective / I_mod_ctrl Tn eff
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r1633 Current model, flux setpoint / I_mod flux setp
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]