List of parameters
Parameters
1-857
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p4400
Description: Setting to invert the position actual value for Terminal Module 41 (TM41).
0 -> Position actual value (CI: p4420) is evaluated as normal.
1 -> Position actual value (CI: p4420) is processed inverted.
Dependency: Refer to: p4420
Description: Sets pulse number to output the zero mark for the incremental encoder simulation/emulation.
Example:
p0408 = 2048 (encoder pulses)
p4426 = 512 (pulses for the zero mark)
--> Position direction: The zero mark is output after 512 pulses.
--> Negative direction: The zero mark is output after 1536 pulses.
Dependency: Refer to: p0408
Note: The pulses for the zero mark (p4426) must be less than the encoder pulse number (p0408).
For p4400 = 1, this parameter has not effect.
Description: Sets the sensor type of the first temperature sensor for the motor temperature monitoring.
The parameter can only be changed for SME120, SME125, CU310 and CUA32.
Values: 0: No sensor available
10: PTC fault
11: PTC alarm
12: PTC alarm and timer stage
20: KTY84
30: Bimetallic NC contact fault
31: Bimetallic NC contact alarm
32: Bimetallic NC contact alarm and timer stage
Dependency: Refer to: r0458, p0600, p0601
Note: PTC thermistor: Tripping resistance = 1650 Ohm
p4422 TM41 position actual value inversion / TM41 s_act inv
TM41 Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 9676
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p4426 Incremental encoder emulation, pulses for zero mark / Enc_emul pulses ZM
TM41 Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 9674
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 8192 0
p4600[0...n] Motor temperature sensor 1 sensor type / MotTemp_sens typ 1
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: EDS, p0140 Func. diagram: 8016
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 32 0