EasyManua.ls Logo

Siemens SINAMICS S Series - p3047 Motor identification - torque characteristic kT5; MotId kT5; p3048 Motor identification - torque characteristic kT7; MotId kT7; p3050[0...n] Motor identification - stator resistance; MotId R_stator; p3054[0...n] Motor identification - rotor resistance; MotId R_rotor

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-690
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p3045, p3047, p3048
Description: Constant kT5 for the torque characteristic set from the motor identification:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p3045, p3046, p3048
Description: Constant kT7 for the torque characteristic set from the motor identification:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency: Refer to: p3045, p3046, p3047
Description: Motor stator resistance measured from the motor identification.
Description: Rotor resistance of the motor measured from the motor identification.
Dependency: Refer to: p0625
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
p3047 Motor identification - torque characteristic kT5 / MotId kT5
SERVO (Exp M_ctrl) Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -
p3048 Motor identification - torque characteristic kT7 / MotId kT7
SERVO (Exp M_ctrl) Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- - -
p3050[0...n] Motor identification - stator resistance / MotId R_stator
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 16_1 Unit selection: p0349
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00000 [Ohm] 2000.00000 [Ohm] 0.00000 [Ohm]
p3054[0...n] Motor identification - rotor resistance / MotId R_rotor
SERVO Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor identification Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL Expert list: 1
Min Max Factory setting
0.00000 [Ohm] 300.00000 [Ohm] 0.00000 [Ohm]