Siemens SINAMICS S Series - p1611[0...n] Supplementary accelerating torque (SLVC); M_suppl_accel; p1612[0...n] Current setpoint, open-loop control, sensorless; I_setCtrSensorless; p1616[0...n] Current setpoint smoothing time; I_set T_smooth; r1618 Current model controller, pre-control; I_mod_ctrl prectrl

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-453
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Enters the dynamic torque setpoint for the low-speed range for sensorless vector control (SLVC). This parameter is
entered as a percentage referred to the rated motor torque (r0333).
Note: When accelerating and braking p1611 is added to p1610 and the resulting total torque is converted into an appro-
priate current setpoint and controlled.
For pure accelerating torques, it is always favorable to use the torque pre-control of the speed controller (p1496).
Description: Sets the current setpoint for controlled (open-loop) sensorless operation.
Note: The value is effective at speeds less than p1755 and represents a reserve for a possibly existing load torque or
torque error in the moment of inertia.
Description: Sets the smoothing time for the current setpoint.
The current setpoint is generated from p1610 and p1611.
Note: This parameter is only effective in the range where current is impressed for sensorless vector control.
Description: Displays the pre-control value of the current model controller. It involves a magnetizing current in the de-direction.
p1611[0...n] Supplementary accelerating torque (SLVC) / M_suppl_accel
VECTOR (n/M) Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6722
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.0 [%] 200.0 [%] 0.0 [%]
p1612[0...n] Current setpoint, open-loop control, sensorless / I_setCtrSensorless
SERVO Can be changed: U, T Calculated: CALC_MOD_REG Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p1616[0...n] Current setpoint smoothing time / I_set T_smooth
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6722
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
4 [ms] 10000 [ms] 40 [ms]
r1618 Current model controller, pre-control / I_mod_ctrl prectrl
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]