EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-73 2483 - IF1 send telegram, free interconnection via BICO (p0922 = 999)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROFIdrive
Function Diagrams
2-1181
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-73 2483 – IF1 send telegram, free interconnection via BICO (p0922 = 999)
- 2483 -
Function diagram
87654321
fp_2483_01_eng.vsd
DO: A_INF, B_INF, CU_S, S_INF, TB30, TM15DI_DO, TM31
SINAMICS S
29.06.07 V02.05.01
PROFIdrive - IF1 send telegram, free interconnection via BICO (p0922 = 999)
<1> In order to maintain the PROFIdrive profile, send word 1 must be used as status word 1 (E_ZSW1) for A_INF, B_INF and S_INF.
<2> Using the binector/connector converters at [2472], bits of 4 send words can be interconnected with any binectors.
<3> The following representation applies for words: 4000 hex = 100 %.
The reference variables p200x apply for the ongoing interconnection (100 % -> p200x).
The following applies for temperature values: 100 °C -> 100 % = 4000 hex; 0 °C -> 0 %.
<4> Valid for CU_S.
<5> Valid for A_INF, B_INF, S_INF.
Refer to [1020.7]
PROFIdrive Abtastzeit
<3>
<1>
PZD send word 7(0)
p2051[6]
<4>
PZD send word 8
PZD send word 13
PZD send word 14
PZD send word 15
<4>
<4>
<4>
<4>
<4>
<4>
(0)
p2051[7]
(0)
p2051[12]
(0)
p2051[13]
(0)
p2051[14]
<4>
<4>
<4>
<4>
<4>
<5>
<5>
<5>
<5>
<5>
PROFIBUS
PROFINET
Drive object n
Header
Drive object 1
Drive object 2
.
.
.
.
.
.
Drive object m
Trailer
IF1 Diag send word 1...7
r2053[0...6]
...
PZD send word 1
PZD send word 2
PZD send word 3
PZD send word 4
PZD send word 5
<2>
(0)
p2051[1]
(0)
p2051[2]
(0)
p2051[3]
(0)
p2051[4]
(0)
p2051[0]
PZD send word 6(0)
p2051[5]
PROFIdrive send telegram
Reference quantities for further interconnection
p200x
<4>
<5>

Table of Contents