List of parameters
Parameters
1-121
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the power unit fan operating hours.
The number of hours operated can only be reset to 0 in this parameter (e.g. after a fan has been replaced).
Dependency: Refer to: p0252
Description: Sets the maximum operating time of the power unit fan.
The pre-alarm (warning) is output 500 hours before this set value.
The monitoring is de-activated with p0252 = 0.
Dependency: Refer to: p0251
Note: For chassis units, the maximum operating duration in the power unit parameter is set to 50000 via the factory set-
ting.
Description: Sets starting time 1 to monitor the cooling system after power on command.
After powering-up, the following signals must be present within starting time 1:
- "RKA powered-up"
- "RKA liquid flow OK"
When a fault occurs, an appropriate message is output.
Dependency: Refer to: F49152, F49153
Note: RKA: Cooling system
p0251[0...n] Operating hours counter power unit fan / PU fan t_oper
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [h] 4294967295 [h] 0 [h]
p0252 Maximum operating time power unit fan / PU fan t_oper max
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: T Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 [h] 50000 [h] 40000 [h]
p0260 Cooling system, starting time 1 / RKA start time 1
A_INF (Cooling sys-
tem), B_INF (Cool-
ing system), SERVO
(Cooling system),
S_INF (Cooling sys-
tem), VECTOR
(Cooling system)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 9795
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [s] 60.0 [s] 5.0 [s]