Siemens SINAMICS S Series - p2603 EPOS flying referencing, positioning mode, relative; Pos_mode relative; p2604 BI: EPOS search for reference, start direction; Srch for ref dir; p2605 EPOS search for reference, approach velocity, reference cam; v_appr ref_cam

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-653
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: The inner window must be set so that it is smaller than the outer window.
Note: If the difference between the reference point coordinate and detected actual position is greater than the outer win-
dow, then no correction is executed for the referenced axis. Further, an appropriate message is output and r2684.3
is set to 1.
Description: Sets the relative positioning mode for flying referencing.
Value = 1:
The corrected setpoint is not calculated into the traversing distance.
Value = 0:
The corrected setpoint is calculated into the traversing distance.
Dependency: Refer to: p2597, p2623, p2648
Caution: For p2603 = 0 the direction can change.
Description: Sets the signal sources for the start direction of the search for reference.
1 signal: Start in the negative direction.
0 signal: Start in the positive direction.
Dependency: Refer to: p2583, p2595, p2597
Description: Sets the approach velocity to the reference cam for the search for reference.
Dependency: The search for reference only starts with the approach velocity to the reference cam when there is a reference cam
(p2607 = 1).
Refer to: p2595, p2597, p2604, p2606, p2607
Note: When traversing to the reference cam, the velocity override is effective.
If, at the start of the search for reference, the axis is already at the reference cam, then the axis immediately starts
to traverse to the zero mark.
p2603 EPOS flying referencing, positioning mode, relative / Pos_mode relative
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 1
p2604 BI: EPOS search for reference, start direction / Srch for ref dir
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2605 EPOS search for reference, approach velocity, reference cam / v_appr ref_cam
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 [1000 LU/min] 40000000 [1000 LU/min] 5000 [1000 LU/min]