List of parameters
Parameters
1-463
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the numerator natural frequency for current setpoint filter 1 (general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the numerator damping for current setpoint filter 1.
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the current setpoint filter 2 as low pass (PT2) or as extended general 2nd-order filter.
Values: 1: Low pass: PT2
2: General 2nd-order filter
p1658[0...n] Current setpoint filter 1 denominator natural frequency / I_set_filt 1 fn_n
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1659[0...n] Current setpoint filter 1 denominator damping / I_set_filt 1 D_n
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1660[0...n] Current setpoint filter 1 numerator natural frequency / I_set_filt 1 fn_z
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1661[0...n] Current setpoint filter 1 numerator damping / I_set_filt 1 D_z
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 10.000 0.700
p1662[0...n] Current setpoint filter 2 type / I_set_filt 2 Typ
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
1 2 1