Siemens SINAMICS S Series - r7022[0...n] CO: Par_circuit deviation current in phase W; Phase W curr dev; r7025 CO: Par_circuit max. deviation currents phase U; Phase U Max i_dev; r7026 CO: Par_circuit max. deviation currents phase V; Phase V Max i_dev; r7027 CO: Par_circuit max. deviation currents phase W; Phase W Max i_dev

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-889
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the deviation between the measured current actual value of phase W and the average value as peak
value.
The maximum deviation from the average value is displayed in r7027.
Dependency: Refer to: r7020, r7021, r7027
Description: Displays the maximum absolute deviation of the measured current actual values of phase U from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7020.
Dependency: Refer to: r7020, r7026, r7027
Refer to: A05052
Description: Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency: Refer to: r7021, r7025, r7027
Refer to: A05052
Description: Displays the maximum absolute deviation of the measured current actual values of phase W from the average
value as peak value.
The deviation of the individual currents from the average value is displayed in r7022.
Dependency: Refer to: r7022, r7025, r7026
Refer to: A05052
r7022[0...n] CO: Par_circuit deviation current in phase W / Phase W curr dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7025 CO: Par_circuit max. deviation currents phase U / Phase U Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7026 CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7027 CO: Par_circuit max. deviation currents phase W / Phase W Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]