EasyManua.ls Logo

Siemens SINAMICS S Series - r3770 CO: APC load speed; APC n_load; r3770 CO: APC load velocity; APC v_load; r3771 CO: APC load speed smoothed; APC n_load smth; r3771 CO: APC load velocity smoothed; APC v_load smth

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-741
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the load speed for APC (Advanced Positioning Control).
Dependency: Refer to: r3771
Description: Displays the load velocity for APC (Advanced Positioning Control).
Dependency: Refer to: r3771
Description: Displays the smoothed load speed for APC (Advanced Positioning Control).
Dependency: Refer to: p1441, r3770
Description: Displays the smoothed load velocity for APC (Advanced Positioning Control).
Dependency: Refer to: p1441, r3770
Description: Displays the speeds in filter branch 2.
Index: [0] = Filter 2.1 input value
[1] = Filter 2.2 output value
r3770 CO: APC load speed / APC n_load
SERVO (APC) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 7012
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r3770 CO: APC load velocity / APC v_load
SERVO (APC, Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 7012
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r3771 CO: APC load speed smoothed / APC n_load smth
SERVO (APC) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 7012
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r3771 CO: APC load velocity smoothed / APC v_load smth
SERVO (APC, Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 7012
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r3772[0...1] APC filter branch 2 display values / APC branch 2 val
SERVO (APC) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 7012
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]