Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 4th value pair of the friction characteristic.
Dependency: Refer to: p3823, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3824, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3824, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3825, p3845
p3833[0...n] Friction characteristic, value F3 / Friction F3
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3834[0...n] Friction characteristic, value M4 / Friction M4
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3834[0...n] Friction characteristic, value F4 / Friction F4
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3835[0...n] Friction characteristic, value M5 / Friction M5
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]