List of parameters
Parameters
1-623
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to select the measuring probe.
1 signal = measuring probe 2 is activated for BI: p2509 = 0/1 edge.
0 signal = measuring probe 1 is activated for BI: p2509 = 0/1 edge.
Index: [0] = Cl.-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency: Refer to: p2502, p2509, p2511
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2509[0] = r2684.1
The measuring probe is selected at the 0/1 signal transition at r2684.1 (flying referencing active).
Description: Sets the signal source for the edge evaluation of the measuring probe.
1 signal = falling edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
0 signal = rising edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
Index: [0] = Cl.-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency: Refer to: p2502, p2509, p2510
Description: Sets the signal source for the function "activate position actual value preprocessing, corrective value (edge)".
0/1 signal: The corrective value available through CI: p2513 is activated.
Index: [0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency: Refer to: p2502, p2513, r2684
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2512[0] = r2684.7
p2510[0...3] BI: LR selecting measuring probe evaluation / MT_eval select
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3615, 4010
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2511[0...3] BI: LR measuring probe evaluation edge / MT_eval edge
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3615, 4010
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2512[0...3] BI: LR pos. actual value preprocessing activate corr. value (edge) /
ActVal_prepCorrAct
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4010, 4015
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0