List of faults and alarms
Faults and Alarms
3-1631
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
47: Pos. act. val. - limit value SLS2 / safety monitoring clock cycle.
48: Pos. act. val. + limit value SLS3 / safety monitoring clock cycle.
49: Pos. act. val. - limit value SLS3 / safety monitoring clock cycle.
50: Pos. act. val. + limit value SLS4 / safety monitoring clock cycle.
51: Pos. act. val. - limit value SLS4 / safety monitoring clock cycle.
52: Standstill position + tolerance.
53: Standstill position - tolerance
54: Pos. act. val. + limit value nx / safety monit. clock cycle + tolerance.
55: Pos. act. val. + limit value nx / safety monit. clock cycle.
56: Pos. act. val. - limit value nx / safety monit. clock cycle.
57: Pos. act. val. - limit value nx / safety monit. clock cycle - tolerance.
58: Actual stop request.
75: Velocity limit nx (p9546, p9346).
76: Stop response for SLS1 (p9563[0], p9363[0]).
77: Stop response for SLS2 (p9563[1], p9363[1]).
78: Stop response for SLS3 (p9563[2], p9363[2]).
79: Stop response for SLS4 (p9563[3], p9363[3]).
81: Velocity tolerance for SBR (p9548, p9348).
82: SGEs for SLS correction factor.
83: Acceptance test timer (p9558, p9358).
84: Trans. time STOP F (p9555, p9355).
85: Trans. time bus failure (p9580, p9380).
86: Ident. 1-encoder system.
87: Encoder assignment, 2nd channel (p9526, p9326).
89: Encoder limit freq.
1000: Watchdog timer has expired. Too many signal changes have occurred at safety-relevant inputs.
1001: Initialization error of watchdog timer.
1005: Pulses already canceled for test stop selection.
1011: Acceptance test status between the monitoring channels differ.
1012: Plausibility violation of the actual value from the encoder.
1020: Cyc. communication failure between the monit. cycles.
1021: Cyc. communication failure between the monit. channel and Sensor Module.
1030: Encoder fault detected from another monitoring channel.
1031: Data transfer error between the monitoring channel and the Sensor Module.
5000 ... 5140: PROFIsafe message values.
Message values 5000, 5014, 5023, 5024, 5030 ... 5032, 5042, 5043, 5052, 5053, 5068, 5072, 5073, 5082 ... 5087,
5090, 5091, 5122 ... 5125, 5132 ... 5135, 5140:
- an int. SW error has occurred. Only for int. Siemens troubleshooting.
5012: Error when initializing the PROFIsafe driver.
5013: The result of the initialization is different for the two controllers.
5022: Error when evaluating the F parameters. The values of the transferred F parameters do not match the
expected values in the PROFIsafe driver.
5025: The result of the F parameterization is different for the two controllers.
5026: CRC error for the F parameters. The transferred CRC value of the F parameters does not match the value
calculated in the PST.
5065: A communications error was identified when receiving the PROFIsafe telegram.
5066: A time monitoring error (timeout) was identified when receiving the PROFIsafe telegram.
See also: p9555 (SI motion transition time STOP F to STOP B (Control Unit)), r9725 (SI motion, diagnostics STOP F)