List of parameters
Parameters
1-265
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
4260: r4260 (set/resetting time digital output 10)
4261: r4261 (set/resetting time digital output 11)
4262: r4262 (set/resetting time digital output 12)
4263: r4263 (set/resetting time digital output 13)
4264: r4264 (set/resetting time digital output 14)
4265: r4265 (set/resetting time digital output 15)
4266: r4266 (set/resetting time digital output 16)
4267: r4267 (set/resetting time digital output 17)
4268: r4268 (set/resetting time digital output 18)
4269: r4269 (set/resetting time digital output 19)
4270: r4270 (set/resetting time digital output 20)
4271: r4271 (set/resetting time digital output 21)
4272: r4272 (set/resetting time digital output 22)
4273: r4273 (set/resetting time digital output 23)
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
[25] = PZD 26
[26] = PZD 27
[27] = PZD 28
[28] = PZD 29
[29] = PZD 30
Note: Example:
The telegram for the setpoints should have the following process data (PZD) and assignments:
PZD 1 (r4201), PZD 2 (r4204), PZD 3 (r4250)
The setpoint assignment must be realized as follows:
p0915[0] = 4201 - 16 bit
p0915[1] = 4204 - 16 bit
p0915[2] = 4250 - 16 bit
p0915[3] = 0
...
p0915[29] = 0