Parameters for data sets
Parameters
1-1071
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
p1513[0...n] CI: Supplementary force 2 / F_suppl 2
p1522[0...n] CI: Torque limit upper/motoring / M_max upper/mot
p1522[0...n] CI: Force limit upper/motoring / F_max upper/mot
p1522[0...n] CI: Torque limit upper / M_max upper
p1523[0...n] CI: Torque limit lower/regenerative / M_max lower/regen
p1523[0...n] CI: Force limit lower/regenerative / F_max lower/regen
p1523[0...n] CI: Torque limit lower / M_max lower
p1528[0...n] CI: Torque limit upper/motoring scaling / M_max up/mot scal
p1528[0...n] CI: Force limit upper/motoring scaling / F_max up/mot scal
p1528[0...n] CI: Torque limit upper scaling / M_max upper scal
p1529[0...n] CI: Torque limit lower/regenerating scaling / M_max low/gen scal
p1529[0...n] CI: Force limit lower/regenerative scaling / F_max low/gen scal
p1529[0...n] CI: Torque limit lower scaling / M_max lower scal
p1540[0...n] CI: Torque limit speed controller upper scaling / M_max n-ctr upScal
p1541[0...n] CI: Torque limit. speed controller lower scaling / M_max nctr lowScal
p1542[0...n] CI: Travel to fixed stop torque reduction / TfS M_red
p1542[0...n] CI: Travel to fixed stop force reduction / TfS F_red
p1545[0...n] BI: Activates travel to a fixed stop / TfS activation
p1550[0...n] BI: Transfer actual torque as torque offset / Accept act torque
p1550[0...n] BI: Transfer actual force as force offset / Accept act force
p1551[0...n] BI: Torque limit variable/fixed signal source / M_lim var/fixS_src
p1551[0...n] BI: Force limit variable/fixed signal source / F_lim var/fixS_src
p1552[0...n] CI: Torque limit upper scaling without offset / M_max up offs scal
p1552[0...n] CI: Force limit upper scaling without offset / F_max up offs scal
p1554[0...n] CI: Torque limit lower scaling without offset / M_max low offsScal
p1554[0...n] CI: Force limit lower scaling without offset / F_max low offsScal
p1555[0...n] CI: Power limit / P_max
p1569[0...n] CI: Supplementary torque 3 / M_suppl 3
p1569[0...n] CI: Supplementary force 3 / F_suppl 3
p1571[0...n] CI: Supplementary flux setpoint / Suppl flux setp
p1640[0...n] CI: Excitation current actual value / I_exc_act val
p2103[0...n] BI: 1. Acknowledge faults / 1. Acknowledge
p2104[0...n] BI: 2. Acknowledge faults / 2. Acknowledge
p2105[0...n] BI: 3. Acknowledge faults / 3. Acknowledge
p2106[0...n] BI: External fault 1 / External fault 1
p2107[0...n] BI: External fault 2 / External fault 2
p2108[0...n] BI: External fault 3 / External fault 3
p2112[0...n] BI: External alarm 1 / External alarm 1
p2116[0...n] BI: External alarm 2 / External alarm 2
p2117[0...n] BI: External alarm 3 / External alarm 3
p2144[0...n] BI: Motor stall monitoring enable (negated) / Mot stall enab neg
p2148[0...n] BI: Ramp-function generator active / HLG active
p2151[0...n] CI: Speed setpoint for messages/signals / n_set for msg
p2151[0...n] CI: Velocity setpoint for messages/signals / v_set for msg
p2154[0...n] CI: Speed setpoint 2 / n_set 2
p2154[0...n] CI: Velocity setpoint 2 / v_set 2
p2200[0...n] BI: Technology controller enable / Tec_ctrl enable
p2220[0...n] BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
p2221[0...n] BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
p2222[0...n] BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
p2223[0...n] BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
p2235[0...n] BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
p2236[0...n] BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower