Overview of parameters
Parameters
1-15
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Examples:
p1070 CI: Main setpoint
SERVO (extended setpoint), VECTOR
The parameter is available only in association with drive object SERVO and
the "Extended setpoint channel" function module or with drive object VECTOR
irrespective of activated function modules.
p1055 BI: Jog bit 0
SERVO, VECTOR
The parameter is available in association with drive objects SERVO and
VECTOR irrespective of activated function modules, i.e. it is available with
every activated function module belonging to the drive object.
A parameter can belong to either one, several, or all drive objects.
The following information relating to "Drive object" and "Function module" can be
displayed under the parameter number:
Table 1-1 Data in "Drive object (function module)" field
Drive object
(function module)
Type Meaning
All objects - This parameter belongs to all drive objects.
A_INF 10 Active Infeed closed-loop control
Closed-loop-controlled, self-commutated infeed/regenerative feed-
back unit for generating a constant DC-link voltage.
A_INF (parallel) - Active Infeed with "Parallel connection" function module (r0108.15).
A_INF (RKA) - Active Infeed with "Cooling system" function module (r0108.28).
A_INF (CBE) - Active Infeed with "CBE COMMUNICATION BOARD" function module
(r0108.31).
B_INF 30 Basic Infeed closed-loop control
Unregulated line infeed unit (without feedback) for rectifying the line
voltage of the DC Link.
B_INF (parallel) - Basic Infeed with "Parallel connection" function module (r0108.15).
B_INF (RKA) - Basic Infeed with "Cooling system" function module (r0108.28).
B_INF (CBE) - Basic Infeed with "CBE COMMUNICATION BOARD" function module
(r0108.31).
CU - Control Unit, all versions.
CU(CAN) - Control Unit with "CAN" function module.
CU_S 1 Control Unit SINAMICS S (SINAMICS S120/S150).
CU_S (CAN) - Control Unit SINAMICS S with "CAN" function module
CU_CX32 - Controller Extension for boosting the processing performance.
CU_LINK 254 Object for Controller Extension 32 (CX32).
CU_I - Control Unit SINAMICS Integrated (SIMOTION D4xx only).
DMC20 150 DRIVE-CLiQ Hub Module Cabinet.