Overview of parameters
Parameters
1-21
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dynamic index
For parameters with a dynamic index [0...n], the following information is specified
here:
Data set (if this is available).
Parameter for the number of indices (n = number - 1).
The following information can be contained in this field:
"CDS, p0170" (Command Data Set, CDS count)
Example:
p1070[0] Æ main setpoint [command data set 0]
p1070[1] Æ main setpoint [command data set 1], etc.
"DDS, p0180" (Drive Data Set, DDS count)
"EDS, p0140" (Encoder Data Set, EDS count)
"MDS, p0130" (Motor Data Set, MDS count)
"PDS, p0120" (Power unit Data Set, PDS count)
"p2615" (traversing blocks count)
BO: Integer32 x
BO: FloatingPoint32––––
Legend:
x: BICO interconnection permitted
–: BICO interconnection not permitted
1 Exception:
BICO input parameters with data type "Unsigned32 / FloatingPoint32" can also be interconnected with the following
BICO output parameters although these are not of the "FloatingPoint32" data type:
CO: r8850
CO: r8860
CO: r2050
CO: r2060
Table 1-2 Possible combinations of BICO interconnections, continued
BICO input parameter
CI parameter BI parameter
BICO output parameter Unsigned32 /
Integer16
Unsigned32 /
Integer32
Unsigned32 /
FloatingPoint32
Unsigned32 /
Binary
Note:
Information on the data sets can be taken from the following references:
References: /FH1/ SINAMICS S120 Function Manual Drive Functions
Section "Data sets"