14.5.3.4 CPTS_TS_LOAD_VAL Register (offset = 10h) [reset = 0h]
CPTS_TS_LOAD_VAL is shown in Figure 14-81 and described in Table 14-93.
TIME STAMP LOAD VALUE REGISTER
Figure 14-81. CPTS_TS_LOAD_VAL Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
TS_LOAD_VAL
R/W-0h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 14-93. CPTS_TS_LOAD_VAL Register Field Descriptions
Bit Field Type Reset Description
31-0 TS_LOAD_VAL R/W 0h Time Stamp Load Value - Writing the ts_load_en bit causes the
value contained in this register to be written into the time stamp.
The time stamp value is read by initiating a time stamp push event,
not by reading this register.
When reading this register, the value read is not the time stamp, but
is the value that was last written to this register.
1313
SPRUH73H–October 2011–Revised April 2013 Ethernet Subsystem
Submit Documentation Feedback