EasyManua.ls Logo

Texas Instruments AM335 Series

Texas Instruments AM335 Series
4161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ethernet Subsystem Registers
www.ti.com
14.5.8.10 FLOW_CONTROL Register (offset = 24h) [reset = 1h]
FLOW_CONTROL is shown in Figure 14-193 and described in Table 14-210.
FLOW CONTROL
Figure 14-193. FLOW_CONTROL Register
31 30 29 28 27 26 25 24
Reserved
23 22 21 20 19 18 17 16
Reserved
15 14 13 12 11 10 9 8
Reserved
7 6 5 4 3 2 1 0
Reserved P2_FLOW_EN P1_FLOW_EN P0_FLOW_EN
R/W-0 R/W-0 R/W-0
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 14-210. FLOW_CONTROL Register Field Descriptions
Bit Field Type Reset Description
2 P2_FLOW_EN R/W-0 0
Port 2 Receive flow control enable
1 P1_FLOW_EN R/W-0 0
Port 1 Receive flow control enable
0 P0_FLOW_EN R/W-0 0
Port 0 Receive flow control enable
1434
Ethernet Subsystem SPRUH73HOctober 2011Revised April 2013
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated

Table of Contents

Other manuals for Texas Instruments AM335 Series

Related product manuals