Start
End
Operational mode: NOR interfacing
Type
of access?
Synchronous
read
Asynchronous
read
Synch
read
operation
ronous Asynch
read
operation
ronous
Type
of access?
Asynchronous
write
Synchronous
write
Synchronous
write
operation
Asynchronous
write
operation
No Write Access
No read access
www.ti.com
GPMC
7.1.3.9 GPMC Timing Parameters
Figure 7-43 shows a programming model diagram for the NOR interfacing timing parameters.
Table 7-41 lists bit fields to configure adequate timing parameter in various memory modes.
Figure 7-43. NOR Interfacing Timing Parameters Diagram
343
SPRUH73H–October 2011–Revised April 2013 Memory Subsystem
Submit Documentation Feedback