TBCTL[SYNCOSEL]
TBPRD
Period Active
TBPRD
Period Shadow
16
TBCTL[SWFSYNC]
CTR = PRD
TBPHS
Phase Active Reg
Counter
UP/DOWN
16
Sync
Out
Select
EPWMxSYNCO
Reset
Load
16
TBCTL[PHSEN]
CTR = 0
CTR = CMPB
Disable
X
EPWMxSYNCI
TBCTL[PRDLD]
TBCNT
Mode
TBCTL[CTRMODE]
CTR = 0
CTR_max
TBCLK
Clock
Prescale
SYSCLKOUT
TBCLK
TBCTL[HSPCLKDIV]
TBCTL[CLKDIV]
CTR_dir
TBCNT
Counter Active Reg
clk
Max
Dir
Zero
www.ti.com
Enhanced PWM (ePWM) Module
15.2.2.3.2 Controlling and Monitoring the Time-Base Submodule
Table 15-11 lists the registers used to control and monitor the time-base submodule.
Table 15-11. Time-Base Submodule Registers
Acronym Register Description Address Offset Shadowed
TBCTL Time-Base Control Register 0h No
TBSTS Time-Base Status Register 2h No
TBPHSHR HRPWM extension Phase Register
(1)
4h No
TBPHS Time-Base Phase Register 6h No
TBCNT Time-Base Counter Register 8h No
TBPRD Time-Base Period Register Ah Yes
(1)
This register is available only on ePWM instances that include the high-resolution extension (HRPWM). On ePWM modules that
do not include the HRPWM, this location is reserved. See Section 15.1.2 to determine which ePWM instances include this
feature.
Figure 15-10 shows the critical signals and registers of the time-base submodule. Table 15-12 provides
descriptions of the key signals associated with the time-base submodule.
Figure 15-10. Time-Base Submodule Signals and Registers
1503
SPRUH73H–October 2011–Revised April 2013 Pulse-Width Modulation Subsystem (PWMSS)
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated