CEVT1
CEVT2
CEVT3
CEVT4
CEVT1
FFFFFFFF
CTR[0−31]
00000000
CAPx pin
t
MOD4
CTR
CAP1
CAP2
CAP3
CAP4
Capture registers [1−4]
CEVT2
CEVT1 CEVT3
CEVT4
t
1
t
2
t
3
t
4
t
5
t
6
t
7
t
8
t
9
0 1 2 3 0 1 2 3 0
XX t
1
t
5
XX t
2
t
6
XX t
3
t
7
XX t
4
t
8
Polarity selection
t
www.ti.com
Enhanced Capture (eCAP) Module
15.3.3.2 Absolute Time-Stamp Operation Rising and Falling Edge Trigger Example
In Figure 15-110 the eCAP operating mode is almost the same as in the previous section except capture
events are qualified as either rising or falling edge, this now gives both period and duty cycle information:
Period1 = t
3
t
1
, Period2 = t
5
t
3
, …etc. Duty Cycle1 (on-time %) = (t
2
t
1
) / Period1 x 100%, etc. Duty
Cycle1 (off-time %) = (t
3
t
2
) / Period1 x 100%, etc.
Figure 15-110. Capture Sequence for Absolute Time-Stamp, Rising and Falling Edge Detect
1621
SPRUH73HOctober 2011Revised April 2013 Pulse-Width Modulation Subsystem (PWMSS)
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated

Table of Contents

Other manuals for Texas Instruments AM335 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments AM335 Series and is the answer not in the manual?

Texas Instruments AM335 Series Specifications

General IconGeneral
BrandTexas Instruments
ModelAM335 Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals