7.3.5.27 IRQENABLE_SET_SYS Register (offset = B4h) [reset = 0h]
IRQENABLE_SET_SYS is shown in Figure 7-117 and described in Table 7-137.
Figure 7-117. IRQENABLE_SET_SYS Register
31 30 29 28 27 26 25 24
Reserved
R-0h
23 22 21 20 19 18 17 16
Reserved
R-0h
15 14 13 12 11 10 9 8
Reserved
R-0h
7 6 5 4 3 2 1 0
Reserved Reserved reg_en_ta_sys reg_en_err_sys
R-0h R/W-0h R/W-0h R/W-0h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 7-137. IRQENABLE_SET_SYS Register Field Descriptions
Bit Field Type Reset Description
31-3 Reserved R 0h
2 Reserved R/W 0h
Reserved.
1 reg_en_ta_sys R/W 0h Enable set for system OCP interrupt.
Writing a 1 will enable the interrupt, and set this bit as well as the
corresponding Interrupt Enable Clear Register.
Writing a 0 has no effect.
0 reg_en_err_sys R/W 0h Enable set for system OCP interrupt.
Writing a 1 will enable the interrupt, and set this bit as well as the
corresponding Interrupt Enable Clear Register.
Writing a 0 has no effect.