GPMC
www.ti.com
ADVWROFFTIME are odd) or (CLKACTIVATIONTIME and ADVWROFFTIME are even)
G = (1 + 0.5 * ADVEXTRADELAY) * GPMC_FCLK period otherwise
Case where GPMCFCLKDIVIDER = 0x2
G = 0.5 * ADVEXTRADELAY * GPMC_FCLK period, when (ADVWROFFTIME -
CLKACTIVATIONTIME) is a multiple of 3
G = (1 + 0.5 * ADVEXTRADELAY) * GPMC_FCLK period, when (ADVWROFFTIME -
CLKACTIVATIONTIME - 1) is a multiple of 3
G = (2 + 0.5 * ADVEXTRADELAY) * GPMC_FCLK period, when (ADVWROFFTIME -
CLKACTIVATIONTIME - 2) is a multiple of 3
For OEn falling edge (OEn activated):
Case where GPMC_CONFIG1_i[1-0] GPMCFCLKDIVIDER = 0x0
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period
Case where GPMCFCLKDIVIDER = 0x1
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period, when (CLKACTIVATIONTIME and OEONTIME are
odd) or (CLKACTIVATIONTIME and OEONTIME are even)
H = (1 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period otherwise
Case where GPMCFCLKDIVIDER = 0x2
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period, when (OEONTIME - CLKACTIVATIONTIME) is a
multiple of 3
H = (1 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period, when (OEONTIME - CLKACTIVATIONTIME -
1) is a multiple of 3
H = (2 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period, when (OEONTIME - CLKACTIVATIONTIME -
2) is a multiple of 3
For OEn rising edge (OEn de-activated):
Case where [1-0] GPMCFCLKDIVIDER = 0x0
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period
Case where GPMCFCLKDIVIDER = 0x1
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period, when (CLKACTIVATIONTIME and OEOFFTIME
are odd) or (CLKACTIVATIONTIME and OEOFFTIME are even)
H = (1 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period otherwise
Case where GPMCFCLKDIVIDER = 0x2
H = 0.5 * OEEXTRADELAY * GPMC_FCLK period, when (OEOFFTIME - CLKACTIVATIONTIME) is a
multiple of 3
H = (1 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period, when (OEOFFTIME - CLKACTIVATIONTIME
- 1) is a multiple of 3
H = (2 + 0.5 * OEEXTRADELAY) * GPMC_FCLK period, when (OEOFFTIME - CLKACTIVATIONTIME
- 2) is a multiple of 3
For WEn falling edge (WEn activated):
Case where GPMC_CONFIG1_i[1-0] GPMCFCLKDIVIDER = 0x0
I = 0.5 * WEEXTRADELAY * GPMC_FCLK period
Case where GPMCFCLKDIVIDER = 0x1
I = 0.5 * WEEXTRADELAY * GPMC_FCLK period, when (CLKACTIVATIONTIME and WEONTIME are
odd) or (CLKACTIVATIONTIME and WEONTIME are even)
I = (1 + 0.5 * WEEXTRADELAY) * GPMC_FCLK period otherwise
Case where GPMCFCLKDIVIDER = 0x2
I = 0.5 * WEEXTRADELAY * GPMC_FCLK period, when (WEONTIME - CLKACTIVATIONTIME) is a
multiple of 3
I = (1 + 0.5 * WEEXTRADELAY) * GPMC_FCLK period, when (WEONTIME - CLKACTIVATIONTIME -
350
Memory Subsystem SPRUH73HOctober 2011Revised April 2013
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated

Table of Contents