Table 20-77. RTC_CTRL_REG Register Field Descriptions (continued)
Bit Field Type Reset Description
3 MODE_12_24 R/W 0h Enable
12-hour mode for HOURS and ALARMHOURS registers.
0x0 = 24-hr mode
0x1 = 12-hour mode
2 AUTO_COMP R/W 0h
Enable oscillator compensation mode.
0x0 = No auto compensation
0x1 = Auto compensation enabled
1 ROUND_30S R/W 0h
Enable one-time rounding to nearest minute on next time register
read.
0x0 = No update
0x1 = Time is rounded to the nearest minute
0 STOP_RTC R/W 0h Stop the RTC
32-kHz counter.
0x0 = RTC is frozen
0x1 = RTC is running
3648
Timers SPRUH73H–October 2011–Revised April 2013
Submit Documentation Feedback
Copyright © 2011–2013, Texas Instruments Incorporated